設計 · コンクリート構造
純軸圧縮耐力 NRd
EN 1992-1-1 第 6.1 条による純圧縮を受ける鉄筋コンクリート断面の設計軸圧縮耐力。
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| コンクリート断面積 | m² | ||
| コンクリートの設計圧縮強度 | N/m² | ||
| 主筋の全断面積 | m² | ||
| 主筋の設計降伏強度 | N/m² | ||
| 純軸圧縮耐力 | kN | Result |
例題
= 0.16 m² · = 17,000,000 N/m² · = 0.002513 m² · = 435,000,000 N/m²
= 3,813.16 kN · Source: EN 1992-1-1:2004 Abschnitt 6.1
Scope and standard
EN 1992-1-1 に準拠した鉄筋コンクリート柱および圧縮部材。
- Standard
- EN 1992-1-1:2004、6.1項
- Result
- in kN