設計 · コンクリート構造
等価長方形応力ブロック深さ a (ACI 318)
ACI 318-19 第22.2.2.4.1節による単鉄筋長方形断面のホイットニー等価長方形圧縮応力ブロック深さ: a = (As · fy) / (0.85 · fc · b).
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 引張鉄筋断面積 | mm² | ||
| 鉄筋の規格降伏強度 | N/m² | ||
| コンクリートの設計基準圧縮強度 | N/m² | ||
| 圧縮縁幅 | mm | ||
| 等価応力ブロック深さ | mm | Result |
例題
= 1,500 mm² · = 420,000,000 N/m² · = 28,000,000 N/m² · = 300 mm
= 88.235 mm
Standard and source
- Standard
- ACI 318-19
- Result
- in mm
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
検索は設計 › コンクリート構造で開始されます。
Miaknows the formula catalog and asks for what is missing.