地盤工学 · 沈下
限界動水勾配 icrit
パイピング/ボイリングの限界動水勾配: icrit = (γsat - γw) / γw。
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 地盤の飽和単位体積重量 | kN/m³ | ||
| 水の単位体積重量 | kN/m³ | ||
| 限界動水勾配 | – | Result |
例題
= 20 kN/m³ · = 9.81 kN/m³
= 1.0387 · Source: EN 1997-1:2004 第10.3条
Scope and standard
EN 1997-1第10.3項に基づく上向き浸透流によるボイリング照査。
- Standard
- EN 1997-1:2004、10.3項、式 (10.2)
- Result
- (dimensionless)
Reference to clause and equation, no standard text. The description is written in our own words.