設計 · 組積造構造

壁上端または下端の耐力低減係数

  • タイプ:係数
  • バージョン1
  • 2026/11/13にレビュー済み

無筋組積造壁の上端または下端における耐力低減係数:Φi = 1 - 2 · ei / t。

Φi=1−2⋅eit\displaystyle \Phi_{i} = 1 - 2 \cdot \frac{e_{i}}{t}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

eitΦi

Formula and quantities

SymbolNameUnitNote
ei\displaystyle e_{i}壁上端または下端の設計偏心mmei\displaystyle e_{i} ≥ 0
t\displaystyle t壁厚mmt\displaystyle t > 0
Φi\displaystyle Φ_{i}端部低減係数–Result

Valid if2⋅ei<t\displaystyle 2 \cdot e_{i} < t

例題

ei\displaystyle e_{i} = 36 mm · t\displaystyle t = 240 mm

Φi\displaystyle Φ_{i} = 0.7 · Source: 手計算

Scope and standard

EN 1996-1-1 条項 6.1.2.2(e_i < t / 2 に適用)。

Standard
EN 1996-1-1-2005-a1:2012、6.1.2.2項、式 (6.4)
Result
Φi\displaystyle Φ_{i} (dimensionless)

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Φi\displaystyle Φ_{i} = 0.7= 1 - 2 · (36 mm) / (240 mm)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

検索は設計 › 組積造構造で開始されます。

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.