設計 · 接合部

偏心ブロックせん断耐力 Veff,2,Rd

  • タイプ:耐力
  • バージョン1
  • 2026/11/13にレビュー済み

偏心載荷を受けるボルト群の設計ブロックせん断耐力: Veff,2,Rd = 0.5 · fu · Ant / γM2 + (1 / √(3)) · fy · Anv / γM0。

Veff,2,Rd=0.5⋅fu⋅Ant/γM2+(1/3)⋅fy⋅Anv/γM0\displaystyle V_{\mathrm{eff},2,\mathrm{Rd}} = 0.5 \cdot f_{u} \cdot A_{nt} / \gamma _{\mathrm{M2}} + (1 / \sqrt{3}) \cdot f_{y} \cdot A_{nv} / \gamma _{\mathrm{M0}}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

Veff2RdAntAnvfufy

Formula and quantities

SymbolNameUnitNote
fu\displaystyle f_{u}鋼板の引張強さN/m²
Ant\displaystyle A_{nt}引張を受けるネット面積mm²
γM2\displaystyle \gamma_{\mathrm{M2}}純断面破断に対する部分係数1
fy\displaystyle f_{y}鋼板の降伏強度N/m²
Anv\displaystyle A_{nv}せん断を受けるネット面積mm²
γM0\displaystyle \gamma_{\mathrm{M0}}断面降伏に対する部分係数1
Veff,2,Rd\displaystyle V_{\mathrm{eff},2,\mathrm{Rd}}偏心載荷時のブロックせん断耐力kNResult

例題

fu\displaystyle f_{u} = 510,000,000 N/m² · Ant\displaystyle A_{nt} = 400 mm² · γM2\displaystyle \gamma_{\mathrm{M2}} = 1.25 · fy\displaystyle f_{y} = 355,000,000 N/m² · Anv\displaystyle A_{nv} = 1,200 mm² · γM0\displaystyle \gamma_{\mathrm{M0}} = 1

Veff,2,Rd\displaystyle V_{\mathrm{eff},2,\mathrm{Rd}} = 327.55 kN

Standard and source

Result
Veff,2,Rd\displaystyle V_{\mathrm{eff},2,\mathrm{Rd}} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Veff,2,Rd\displaystyle V_{\mathrm{eff},2,\mathrm{Rd}} = 327.551 kN= 0.5 · (510,000,000 N/m²) · (400 mm²) / (1.25 1) + (1 / sqrt(3)) · (355,000,000 N/m²) · (1,200 mm²) / (1 1)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

検索は設計 › 接合部で開始されます。

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.