設計 · 鋼構造
非溶接部の圧縮域における有効疲労応力範囲 (EN 1993-1-9)
EN 1993-1-9 第7.2.1(1)項による最小応力が圧縮となる非溶接部または応力除去溶接部の有効疲労応力範囲: Δσeff = σmax - 0.6 · σmin.
- EN 1993-1-9:2005
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| サイクル中の最大引張応力 | N/m² | ||
| サイクル中の最小圧縮応力(負値) | N/m² | ||
| 有効疲労応力範囲 | N/m² | Result |
例題
= 60,000,000 N/m² · = -40,000,000 N/m²
= 84,000,000 N/m²
Standard and source
- Standard
- EN 1993-1-9:2005
- Result
- in MPa
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
検索は設計 › 鋼構造で開始されます。