ANSI/AISC 360-22 第J2.4節 式J2-4による等脚すみ肉溶接の単位長さあたり設計耐力: Rd = φ · 0.60 · Fexx · 0.707 · w.

ϕRnw=ϕ⋅0.60⋅FEXX⋅0.707⋅w\displaystyle \phi R_{nw} = \phi \cdot 0.60 \cdot F_{EXX} \cdot 0.707 \cdot w
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

wFexxRd

Formula and quantities

SymbolNameUnitNote
ϕ\displaystyle \phiすみ肉溶接の耐力係数(0.75)1
Fexx\displaystyle F_{exx}溶加材の規格引張強さN/m²
w\displaystyle wすみ肉溶接の脚長mm
Rd\displaystyle R_{\mathrm{d}}単位長さあたり設計溶接耐力kN/mResult

例題

ϕ\displaystyle \phi = 0.75 1 · Fexx\displaystyle F_{exx} = 485,000,000 N/m² · w\displaystyle w = 8 mm

Rd\displaystyle R_{\mathrm{d}} = 1,234.42 kN/m

Standard and source

Standard
AISC 360-22
Result
Rd\displaystyle R_{\mathrm{d}} in kN/m

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Rd\displaystyle R_{\mathrm{d}} = 1,234.42 kN/m= (0.75 1) · 0.60 · (485,000,000 N/m²) · 0.707 · (8 mm)