EN 1993-1-2 第4.2.5.1項 式(4.26a)による標準火災下の無被覆I形断面のシャドウ効果補正係数: ksh = 0.9 · (Sfb / Sf).

ksh=0.9⋅[Am/V]bAm/V\displaystyle k_{sh} = 0.9 \cdot \frac{[A_{m}/V]_{\mathrm{b}}}{A_{m}/V}
  • EN 1993-1-2:2005
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

Formula and quantities

SymbolNameUnitNote
Sfb\displaystyle S_{fb}ボックス包絡断面係数 [Am/V]_bm⁻¹
Sf\displaystyle S_{f}実際の断面係数 Am/Vm⁻¹
ksh\displaystyle k_{sh}シャドウ効果補正係数1Result

例題

Sfb\displaystyle S_{fb} = 167 m⁻¹ · Sf\displaystyle S_{f} = 216 m⁻¹

ksh\displaystyle k_{sh} = 0.6958 1

Standard and source

Standard
EN 1993-1-2:2005
Result
ksh\displaystyle k_{sh} in 1

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

ksh\displaystyle k_{sh} = 0.695833 1= 0.9 · ((167 m⁻¹) / (216 m⁻¹))