柱ウェブの横方向引張耐力 Ft,wc,Rd
無補剛柱ウェブの横方向引張に対する設計耐力: Ft,wc,Rd = ω · beff,t,wc · twc · fy,wc / γM0。
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 柱ウェブパネルのせん断との相互作用に対する低減係数 | 1 | ||
| 柱ウェブ引張有効幅 | mm | ||
| 柱ウェブの板厚 | mm | ||
| 柱ウェブの降伏強度 | N/m² | ||
| 断面耐力に対する部分係数 | 1 | ||
| 柱ウェブの引張耐力 | kN | Result |
例題
= 0.85 · = 160 mm · = 10 mm · = 355,000,000 N/m² · = 1
= 482.8 kN
Standard and source
- Standard
- EN 1993-1-8-2005-ac:2009
- Result
- in kN
Reference to clause and equation, no standard text. The description is written in our own words.