作用・荷重 · 温度作用

壁内自己釣合熱応力 σT,wall

  • タイプ:作用効果
  • バージョン1
  • 2026/11/13にレビュー済み

壁厚方向の線形温度差 δT,M を受ける拘束板または円筒シェル壁の最大弾性表面応力:σT,wall = E · αT · δT,M / (2 · (1 - ν))。

σT,wall=E⋅αT⋅δT,M/(2⋅(1−ν))\displaystyle \sigma _{T,wall} = E \cdot \alpha _{T} \cdot \delta _{T,M} / (2 \cdot (1 - \nu ))
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

σT,wall

Formula and quantities

SymbolNameUnitNote
E\displaystyle E壁材の弾性係数N/m²
αT\displaystyle \alpha_{T}線膨張係数(1/K)1
δT,M\displaystyle \delta_{T,M}壁厚貫通温度差(K)1
ν\displaystyle \nu壁材のポアソン比1
σT,wall\displaystyle \sigma_{T,wall}壁表面熱応力N/m²Result

例題

E\displaystyle E = 33,000,000,000 N/m² · αT\displaystyle \alpha_{T} = 1e-5 · δT,M\displaystyle \delta_{T,M} = 30 · ν\displaystyle \nu = 0.2

σT,wall\displaystyle \sigma_{T,wall} = 6,190,000 N/m²

Standard and source

Result
σT,wall\displaystyle \sigma_{T,wall} in MPa

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
σT,wall\displaystyle \sigma_{T,wall} = 6,187,500 N/m²= (33,000,000,000 N/m²) · (1e-5 1) · (30 1) / (2 · (1 - (0.2 1)))

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

検索は作用・荷重 › 温度作用で開始されます。

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.