설계 · 콘크리트

균열 모멘트 Mcr

  • 유형: 저항
  • 버전 1
  • 2026. 11. 12.에 검토됨

EN 1992-1-1 7.1항 (2)에 따른 철근 콘크리트 단면의 균열 휨 모멘트: Mcr = Wel · fctm.

Mcr=Wel⋅fctm\displaystyle M_{\mathrm{cr}} = W_{\mathrm{el}} \cdot f_{ctm}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

Mcrfctm

Formula and quantities

SymbolNameUnitNote
Wel\displaystyle W_{\mathrm{el}}비균열 콘크리트 전단면의 탄성 단면계수m³
fctm\displaystyle f_{ctm}콘크리트의 평균 인장강도N/m²
Mcr\displaystyle M_{\mathrm{cr}}균열 휨 모멘트NmResult

예제

Wel\displaystyle W_{\mathrm{el}} = 0.015 m³ · fctm\displaystyle f_{ctm} = 2,900,000 N/m²

Mcr\displaystyle M_{\mathrm{cr}} = 43,500 Nm · Source: EN 1992-1-1:2004 조항 7.1 (2)

Scope and standard

EN 1992-1-1에 따른 철근 콘크리트 보 및 슬래브.

Standard
EN 1992-1-1:2004, 7.1 (2) 절
Result
Mcr\displaystyle M_{\mathrm{cr}} in kN*m

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Mcr\displaystyle M_{\mathrm{cr}} = 43,500 Nm= (0.015 m³) · (2,900,000 N/m²)