설계 · 콘크리트
크리프를 고려한 유효 탄성계수 Ec,eff
EN 1992-1-1 식 (5.26)에 따른 크리프를 고려한 콘크리트 유효 탄성계수: Ec,eff = Ecm / (1 + φef).
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 콘크리트 할선 탄성계수 | N/m² | ||
| 유효 크리프비 | 1 | ||
| 콘크리트의 유효 탄성계수 | N/m² | Result |
예제
= 33,000,000,000 N/m² · = 2 1
= 11,000,000,000 N/m² · Source: EN 1992-1-1:2004 식 (5.26)
Scope and standard
EN 1992-1-1에 따른 철근 및 프리스트레스트 콘크리트 구조.
- Standard
- EN 1992-1-1:2004, 5.8.7.2 (1) 절, 식 (5.26)
- Result
- in GPa
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
설계 › 콘크리트에서 검색이 시작됩니다.
Miaknows the formula catalog and asks for what is missing.