지반 공학 · 침하

목표 시간계수 Tv 도달 압밀시간 (EN 1997-1)

  • 유형: 성질
  • 버전 1
  • 2026. 11. 24.에 검토됨

배수거리 Hd와 압밀계수 cv를 갖는 점토층에서 목표 압밀시간계수 Tv에 도달하는 데 필요한 시간: t = (Tv · Hd²) / cv.

t=Tv⋅Hd2cv\displaystyle t = \frac{T_{v} \cdot H_{\mathrm{d}}^2}{c_{v}}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

HdTvtcv

Formula and quantities

SymbolNameUnitNote
Tv\displaystyle T_{v}무차원 시간계수 (예: U = 90%일 때 0.848)1
Hd\displaystyle H_{\mathrm{d}}최대 배수거리m
cv\displaystyle c_{v}압밀계수m²/s
t\displaystyle t소요 압밀시간hResult

예제

Tv\displaystyle T_{v} = 0.848 1 · Hd\displaystyle H_{\mathrm{d}} = 2 m · cv\displaystyle c_{v} = 1e-6 m²/s

t\displaystyle t = 942.22 h

Standard and source

Result
t\displaystyle t in h

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
t\displaystyle t = 942.222 h= ((0.848 1) · (2 m)²) / (1e-6 m²/s)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

지반 공학 › 침하에서 검색이 시작됩니다.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.