지반 공학 · 지지력
인장말뚝 설계 저항력 Rt,d
축하중을 받는 인장말뚝의 설계 인장저항력: Rtd = Rtk / γst.
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 말뚝의 특성 인장저항력 | kN | ||
| 인장말뚝 저항 부분안전계수 | – | ||
| 말뚝의 설계 인장저항력 | kN | Result |
예제
= 500 kN · = 1.15
= 434.78 kN · Source: EN 1997-1:2004 조항 7.6.3.1
Scope and standard
EN 1997-1 7.6.3.1절에 따른 인장말뚝 설계.
- Standard
- EN 1997-1:2004, 7.6.3.1 절, 식 (7.15)
- Result
- in kN
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
지반 공학 › 지지력에서 검색이 시작됩니다.
Miaknows the formula catalog and asks for what is missing.