설계 · 강재
볼트 설계전단강도 (LRFD, AISC)
ANSI/AISC 360-22 제J3.6절 식 J3-1에 따른 전단면당 단일 볼트의 설계전단강도: Rd = φ · Fnv · Ab.
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 강도감소계수 (0.75) | 1 | ||
| 볼트 공칭전단응력 | N/m² | ||
| 볼트 나사산 없는 몸체 공칭단면적 | mm² | ||
| 볼트 설계전단강도 | kN | Result |
예제
= 0.75 1 · = 372,000,000 N/m² · = 314.16 mm²
= 87.65 kN
Standard and source
- Standard
- AISC 360-22
- Result
- in kN
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
설계 › 강재에서 검색이 시작됩니다.
Miaknows the formula catalog and asks for what is missing.