설계 · 강재
냉간성형강 휨-전단 상관 (EN 1993-1-3)
EN 1993-1-3 제6.1.10절에 따른 냉간성형 부재의 휨모멘트-전단력 상관 검토: ηMV = (MEd / Mc,Rd)² + (VEd / Vbw,Rd)².
- EN 1993-1-3:2006
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 설계 휨모멘트 | Nm | ||
| 설계 휨내력 | Nm | ||
| 설계 전단력 | kN | ||
| 웨브 전단좌굴저항 | kN | ||
| 휨 및 전단 상관 검토비 (<= 1.0) | 1 | Result |
예제
= 12,000 Nm · = 18,000 Nm · = 20 kN · = 40 kN
= 0.694444
Standard and source
- Standard
- EN 1993-1-3:2006
- Result
- in 1
Reference to clause and equation, no standard text. The description is written in our own words.