설계 · 강재

전단응력 피로강도 m = 5 (EN 1993-1-9)

  • 유형: 성질
  • 버전 1
  • 2026. 11. 24.에 검토됨

EN 1993-1-9 제7.1(1)절에 따른 기울기 m = 5 (NR <= 1e8 회) 전단응력 범위의 피로강도: ΔτR = ΔτC · (2e6 / NR)^(1/5).

ΔτR=ΔτC⋅(2⋅106NR)1/5\displaystyle \Delta\tau_{R} = \Delta\tau_{\mathrm{C}} \cdot \left(\frac{2 \cdot 10^6}{N_{R}}\right)^{1/5}
  • EN 1993-1-9:2005
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

ΔτCΔτRNR

Formula and quantities

SymbolNameUnitNote
ΔτC\displaystyle \Delta\tau_{\mathrm{C}}200만 회 반복 기준 전단 상세범주 참조강도N/m²
NR\displaystyle N_{R}응력 반복횟수1
ΔτR\displaystyle \Delta\tau_{R}N_R 회 반복 시 전단응력 피로강도N/m²Result

예제

ΔτC\displaystyle \Delta\tau_{\mathrm{C}} = 80,000,000 N/m² · NR\displaystyle N_{R} = 10,000,000

ΔτR\displaystyle \Delta\tau_{R} = 57,982,400 N/m²

Standard and source

Standard
EN 1993-1-9:2005
Result
ΔτR\displaystyle \Delta\tau_{R} in MPa

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
ΔτR\displaystyle \Delta\tau_{R} = 57,982,400 N/m²= (80,000,000 N/m²) · (2000000 / (10,000,000 1))^(1 / 5)