모드 1(플랜지 완전 항복)에 대한 등가 T-스터브 플랜지의 설계 인장내력: FT,1,Rd = 4 · Mpl,1,Rd / m.

FT,1,Rd=4⋅Mpl,1,Rd/m\displaystyle F_{T,1,\mathrm{Rd}} = 4 \cdot M_{\mathrm{pl},1,\mathrm{Rd}} / m
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

FT1RdmMpl1Rd

Formula and quantities

SymbolNameUnitNote
Mpl,1,Rd\displaystyle M_{\mathrm{pl},1,\mathrm{Rd}}T-스터브 플랜지의 소성 휨내력 (모드 1)Nm
m\displaystyle m볼트 중심선에서 소성힌지선까지의 거리mm
FT,1,Rd\displaystyle F_{T,1,\mathrm{Rd}}T-스터브 모드 1 인장내력kNResult

예제

Mpl,1,Rd\displaystyle M_{\mathrm{pl},1,\mathrm{Rd}} = 3,150 Nm · m\displaystyle m = 35 mm

FT,1,Rd\displaystyle F_{T,1,\mathrm{Rd}} = 360 kN

Standard and source

Result
FT,1,Rd\displaystyle F_{T,1,\mathrm{Rd}} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
FT,1,Rd\displaystyle F_{T,1,\mathrm{Rd}} = 360 kN= 4 · (3,150 Nm) / (35 mm)