설계 · 강재

횡비틀림좌굴 설계 저항 모멘트 Mb,Rd

  • 유형: 저항
  • 버전 1
  • 2026. 11. 9.에 검토됨

비지지 보의 횡비틀림좌굴 설계 저항 모멘트: Mb,Rd = χLT · Wy · fy / γM1.

Mb,Rd=χLT⋅Wy⋅fyγM1\displaystyle M_{\mathrm{b},\mathrm{Rd}} = \frac{\chi_{\mathrm{LT}} \cdot W_{y} \cdot f_{y}}{\gamma_{\mathrm{M1}}}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

χLTMb,Rd

Formula and quantities

SymbolNameUnitNote
χLT\displaystyle \chi_{\mathrm{LT}}횡비틀림좌굴 저감계수–
Wy\displaystyle W_{y}단면계수m³
fy\displaystyle f_{y}항복 강도N/mm²
γM1\displaystyle \gamma_{\mathrm{M1}}부재 안정성에 대한 부분계수–
Mb,Rd\displaystyle M_{\mathrm{b},\mathrm{Rd}}설계 좌굴 저항 모멘트NmResult

예제

χLT\displaystyle \chi_{\mathrm{LT}} = 0.622 · Wy\displaystyle W_{y} = 0.0006284 m³ · fy\displaystyle f_{y} = 235 N/mm² · γM1\displaystyle \gamma_{\mathrm{M1}} = 1

Mb,Rd\displaystyle M_{\mathrm{b},\mathrm{Rd}} = 91,853 Nm · Source: EN 1993-1-1:2005 식 (6.55)

Scope and standard

EN 1993-1-1 6.3.2.1에 따른 횡비틀림좌굴에 민감한 보.

Standard
EN 1993-1-1:2005, 6.3.2.1 (3) 절, 식 (6.55)
Result
Mb,Rd\displaystyle M_{\mathrm{b},\mathrm{Rd}} in kN*m

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Mb,Rd\displaystyle M_{\mathrm{b},\mathrm{Rd}} = 91,853.2 Nm= 0.622 · (0.0006284 m³) · (235 N/mm²) / 1

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

설계 › 강재에서 검색이 시작됩니다.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.