설계 · 강재

부재 안정성 상호작용 이용률 (z-z)

  • 유형: 검토
  • 버전 1
  • 2026. 11. 10.에 검토됨

EN 1993-1-1 식 6.62에 따른 z축에 대한 전체 부재 안정성 상호작용 이용률: ηzz = NEd / Nb,z,Rd + kzy · My,Ed / Mb,Rd + kzz · Mz,Ed / Mc,z,Rd <= 1.0.

ηzz=NEd/Nb,z,Rd+kzy⋅My,Ed/Mb,Rd+kzz⋅Mz,Ed/Mc,z,Rd\displaystyle \eta _{zz} = N_{\mathrm{Ed}} / N_{\mathrm{b},z,\mathrm{Rd}} + k_{zy} \cdot M_{y,\mathrm{Ed}} / M_{\mathrm{b},\mathrm{Rd}} + k_{zz} \cdot M_{z,\mathrm{Ed}} / M_{\mathrm{c},z,\mathrm{Rd}}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

NEdNbzRd

Formula and quantities

SymbolNameUnitNote
NEd\displaystyle N_{\mathrm{Ed}}설계 축압축력kN
Nb,z,Rd\displaystyle N_{\mathrm{b},z,\mathrm{Rd}}z축에 대한 설계 좌굴 저항kN
kzy\displaystyle k_{zy}상호작용 계수 k_zy1
My,Ed\displaystyle M_{y,\mathrm{Ed}}y축에 대한 설계 휨모멘트kNm
Mb,Rd\displaystyle M_{\mathrm{b},\mathrm{Rd}}설계 횡비틀림좌굴 저항력kNm
kzz\displaystyle k_{zz}상호작용 계수 k_zz1
Mz,Ed\displaystyle M_{z,\mathrm{Ed}}z축에 대한 설계 휨모멘트kNm
Mc,z,Rd\displaystyle M_{\mathrm{c},z,\mathrm{Rd}}z축에 대한 설계 단면 휨 저항력kNm
ηzz\displaystyle \eta_{zz}부재 안정성 이용률 (z-z)1Result

예제

NEd\displaystyle N_{\mathrm{Ed}} = 80 kN · Nb,z,Rd\displaystyle N_{\mathrm{b},z,\mathrm{Rd}} = 320 kN · kzy\displaystyle k_{zy} = 0.65 · My,Ed\displaystyle M_{y,\mathrm{Ed}} = 50 kNm · Mb,Rd\displaystyle M_{\mathrm{b},\mathrm{Rd}} = 150 kNm · kzz\displaystyle k_{zz} = 1.15 · Mz,Ed\displaystyle M_{z,\mathrm{Ed}} = 8 kNm · Mc,z,Rd\displaystyle M_{\mathrm{c},z,\mathrm{Rd}} = 40 kNm

ηzz\displaystyle \eta_{zz} = 0.697

Standard and source

Result
ηzz\displaystyle \eta_{zz} in 1

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
ηzz\displaystyle \eta_{zz} = 0.696667 1= (80 kN) / (320 kN) + (0.65 1) · (50 kNm) / (150 kNm) + (1.15 1) · (8 kNm) / (40 kNm)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

설계 › 강재에서 검색이 시작됩니다.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.