설계 · 목재

집성재의 휨 및 인장에 대한 깊이계수 kh

  • 유형: 계수
  • 버전 1
  • 2026. 11. 9.에 검토됨

깊이 h < 600 mm인 집성재의 크기효과계수 kh: kh = min((600 mm / h)⁰.1; 1.1).

kh=min⁡((600 mmh)0,1;  1,1)\displaystyle k_{h} = \min\left(\left(\frac{600\text{ mm}}{h}\right)^{0{,}1};\; 1{,}1\right)
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

Formula and quantities

SymbolNameUnitNote
h\displaystyle h단면 깊이mm
kh\displaystyle k_{h}집성재 깊이계수 k_h–Result

예제

h\displaystyle h = 300 mm

kh\displaystyle k_{h} = 1.07177 · Source: EN 1995-1-1:2004 식 (3.2)

Scope and standard

EN 1995-1-1, 3.3절에 따른 깊이 h < 600 mm인 휨 또는 인장 집성목.

Standard
EN 1995-1-1:2004, 3.3 (3) 절, 식 (3.2)
Result
kh\displaystyle k_{h} (dimensionless)

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
kh\displaystyle k_{h} = 1.07177= min((600 [mm] / (300 mm))⁰.1; 1.1)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

설계 › 목재에서 검색이 시작됩니다.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.