Privacy settings

We use Microsoft Clarity to understand how CALC is used — only if you agree. Necessary cookies keep the app working (sign-in, security, free-quota enforcement) and are always active.

SKL-000067 · Skill

EN 1990EN 1993-1-8

Design a bolted end plate connection to Eurocode 3

Describe the column and beam sections, the design forces at the joint, the end plate geometry with its four overhangs, the bolt grid, and the weld throats. Mia builds a small RFEM 6 model, runs the Steel Joints add-on, and reports the governing utilisation across plates, bolts, and welds.

Mia

Mia guides you step by stepShe guides you through the inputs and explains the results.

Worked example

HEB 200 · IPE 300 · NEd 50 kN + VEd 80 kN + MEd 60 kNm

Design verified: fillet weld check governs
HEB 200 · IPE 300 · N_Ed 50 kN + V_Ed 80 kN + M_Ed 60 kNm
System
Beam-to-column joint
Sections
IPE 300 · HEB 200 · S235
Forces
NEd 50 kN · VEd 80 kN · MEd 60 kNm
End plate
15 mm · 65 mm top overhang
Bolts
4x2 M20 gr. 8.8

Design a bolted extended end plate connection between an IPE 300 beam (S235) and a HEB 200 column (S235) with NEd = 50 kN, VEd = 80 kN, MEd = 60 kNm at the joint. End plate 15 mm S235 with a 65 mm top overhang, flush elsewhere, 4 rows x 2 columns of M20 grade 8.8 bolts at 90/90 mm spacing and 30 mm edge distance, 8 mm flange welds and 6 mm web welds, EN-recommended values.

Calculate the example with Mia

Key results

Governing utilization
η = 0.97 (welds)
Bolt utilization
η = 0.56
Plate utilization
η = 0.12

Values from the RFEM 6.16 Steel Joints add-on for the stated inputs. Design forces applied exactly at the joint via a short cantilever stub; EN-recommended partial factors.

  • — Column web and flange are unstiffened.
  • — Bolt rows at the stated spacings, bolt columns centered on the beam web.
  • — ULS configuration of the Steel Joints add-on with RFEM default settings.

Required inputs

  • Joint type: continuous column or frame corner
  • Column and beam cross-sections and steel grades
  • Design forces NEd, VEd, MEd at the joint
  • End plate thickness, grade, and the four overhangs
  • Bolt grid in mm (rows x columns, edge distance, individual row spacings, column spacing), diameter, and grade
  • Flange and web weld throat thickness
  • National Annex

What you receive

  • Governing check and utilisation
  • Plate utilisation (bending/tension components)
  • Bolt utilisation (tension, shear, bearing, or combined)
  • Weld utilisation (flange and web)
  • Table of every design ratio from the RFEM Steel Joints results
  • Assumptions and normative references
Reviewed calculation example

Start from an input template

These templates prefill the form with typical inputs. They are not calculated results; the calculation runs in CALC.

Prepare your calculation
Dlubal CALC
Configure your end plate connection
Structural calculation to standard

System sketch

All required fields completed

Inputs completeReady to calculate

What this skill checks

Self-contained joint model

Builds a minimal column-and-beam model in a new RFEM 6 model from the given cross-sections and applies the stated N_Ed, V_Ed, and M_Ed exactly at the joint. Open models stay untouched.

Continuous column or frame corner

Models the column either running through the joint or ending at it, with a member cut that extends the column to the top edge of the end plate.

Individual bolt row spacings

Configures any rows-by-columns bolt pattern with its own spacing between each pair of bolt rows, a column spacing, and an edge distance, all in mm.

Four-sided plate overhang

Sets the end plate overhang beyond the beam profile independently on all four sides (top, bottom, left, right).

Definable weld throats

Sets the flange and web fillet weld throat thickness independently and reports their utilisation.

Results from the RFEM calculation

Calculates the joint in RFEM 6 with the Steel Joints add-on and an assigned ULS configuration, then reports every design ratio RFEM outputs for plates, bolts, and welds. Nothing is calculated by hand.

Ready for your first check?

Start with the example and adapt it to your structural system.

New calculation