Haunch or prismatic
Rolled base section with a haunch cut from an I section below the bottom flange (three flanges, monosymmetric), a welded I section tapering to a deeper section at the fixed end, or a prismatic cantilever without haunch.
Privacy settings
We use Microsoft Clarity to understand how CALC is used — only if you agree. Necessary cookies keep the app working (sign-in, security, free-quota enforcement) and are always active.

SKL-000138 · Skill
EN 1993-1-1:2005 + AC:2009, 5.2.2, 6.2, 6.3.4DIN EN 1993-1-1/NAEN 1993-1-5, 5.1Enter the length, the haunch at the fixed end or none, the sections and the design loads. Mia computes the internal forces on the deformed system, checks every cross-section along the cantilever and verifies flexural and lateral-torsional buckling with the general method of EN 1993-1-1, 6.3.4.
Mia guides you step by stepShe guides you through the inputs and explains the results.
Design a cantilever IPE 300, length 3 m, haunch of 1 m at the fixed end cut from IPE 300 with hv = 150 mm, qz,Ed = 10 kN/m and Fz,Ed = 10 kN at the tip.
These templates prefill the form with typical inputs. They are not calculated results; the calculation runs in CALC.
Rolled base section with a haunch cut from an I section below the bottom flange (three flanges, monosymmetric), a welded I section tapering to a deeper section at the fixed end, or a prismatic cantilever without haunch.
Internal forces on the deformed system under the axial force N_Ed, without imperfection; compression up to 4 % of the in-plane critical load.
Classification and resistance at every station for N, M_y, M_z and V, including bending and shear interaction.
α_ult,k at the critical cross-section and α_cr,op from a buckling analysis of the cantilever with warping restrained at the fixed end, monosymmetry and load height; χ_op as minimum or interpolated.
With a horizontal load the general method is extended according to Naumes, as in RFEM 6.
Normative basis
The checks follow these standards. Nationally determined parameters come from the National Annex selected in the form.
Edition used: DIN EN 1993-1-1:2010-12 (EN 1993-1-1:2005 + AC:2009) + DIN EN 1993-1-1/A1:2014-07
| Country | National Annex | Factors | Source |
|---|---|---|---|
| DE | DIN EN 1993-1-1/NA:2022-10WithdrawnNewer edition: DIN EN 1993-1-1/NA:2026-04 | γM0 = 1.00γM1 = 1.10 | DIN Media |
| EN | Recommended valuesEN 1993-1-1:2005 + AC:2009 | γM0 = 1.00γM1 = 1.00 | – |
Status checked on
Frequently asked questions
A rolled section with a haunch cut from an I section and welded below the bottom flange, so that the haunch has three flanges and is monosymmetric, and a welded I section whose depth and plates vary linearly to a deeper section at the fixed end. Without a haunch the cantilever is a prismatic rolled section. Mia takes the shear center offset and the Wagner coefficient βz into account.
The cantilever is fully fixed at x = 0, including the warping restraint (ω = 0), and free at x = L. The connection must provide this restraint, for example a stiffened end plate or a continuous member; a fixed end that allows warping lowers αcr,op and is designed in RFEM.
The general method of EN 1993-1-1, 6.3.4. αult,k comes from the internal forces at the critical cross-section, αcr,op from a buckling analysis of the cantilever, and χop from 6.3.4(4) a) or b). With a horizontal load the method is extended according to Naumes for biaxial bending, as RFEM 6 does with its extended method.
Yes, in plane. The axial force NEd acts on the deformed cantilever, so My includes the second-order effect; no imperfection is applied. Mz from a horizontal load stays first order, because the general method covers the out-of-plane effects. Axial compression is limited to 4 % of the in-plane critical load.
All loads are design values. Self-weight, if selected, is applied as 1.35 times 78.5 kN/m³ times the area of the section at each point. Axial force acts at the tip and is positive for tension and negative for compression.
Mia names the limit that is exceeded, for example class 4 or a haunch longer than the cantilever, and does not calculate. The member can then be designed in RFEM.