Stabilizing load
Determines alpha_m, the bow e0 = alpha_m L / 500, and the equivalent load q_d of Eq. (5.13), with the truss deflection delta_q solved exactly from the stiffness of chords, diagonals, and struts.
Privacy settings
We use Microsoft Clarity to understand how CALC is used — only if you agree. Necessary cookies keep the app working (sign-in, security, free-quota enforcement) and are always active.

SKL-000146 · Skill
EN 1993-1-1:2005+AC:2009+A1:2014, 5.3.3, 6.1, 6.2.3, 6.3.1, Table 6.2EN 1993-1-8:2005+AC:2009, 3.6.1(3), 3.10.3, Table 2.1, Table 3.4, Table 3.8DIN EN 1993-1-1/NA:2022-10Enter the span, the bay width, the number of fields, the restrained rafters with their compression force, the design load on the bracing, and the sections. Mia determines the stabilizing load of EN 1993-1-1, 5.3.3, including the truss deflection, the member forces, and the checks of the tension diagonals and the purlin struts.
Mia guides you step by stepShe guides you through the inputs and explains the results.
Check the horizontal roof bracing truss to EN 1993-1-1:2005+AC:2009+A1:2014 with EN 1993-1-8:2005+AC:2009, CEN recommended values. Span L = 24 m, bay width e = 6 m, 4 fields, 6 restrained IPE 450 rafters with NEd = 320 kN each, design load on the bracing qEd = 2.1 kN/m, steel S235, diagonals RD 20, struts CHS 114.3x4.5, strut force from the support reaction, no splice.
Values from the calculation core; an RFEM 6 model with steel design gave the same diagonal utilization 0.684 and 0.414 for the strut.
These templates prefill the form with typical inputs. They are not calculated results; the calculation runs in CALC.
Determines alpha_m, the bow e0 = alpha_m L / 500, and the equivalent load q_d of Eq. (5.13), with the truss deflection delta_q solved exactly from the stiffness of chords, diagonals, and struts.
Combines q_d with the design load q_Ed, gives the support reaction, the end-field shear, and the diagonal force, and checks the local splice force of 5.3.3(4) as a separate case.
Checks the gross section and, for round bars, the threaded end with the stress area, or for a given net area the net section with beta = 0.4 of EN 1993-1-8, Table 3.8.
Checks flexural buckling of the strut with the buckling curve of Table 6.2 for rolled I and H sections or hollow sections.
Normative basis
The checks follow these standards. Nationally determined parameters come from the National Annex selected in the form.
Edition used: DIN EN 1993-1-1:2010-12 (EN 1993-1-1:2005 + AC:2009) + DIN EN 1993-1-1/A1:2014-07
| Country | National Annex | Factors | Source |
|---|---|---|---|
| DE | DIN EN 1993-1-1/NA:2022-10WithdrawnNewer edition: DIN EN 1993-1-1/NA:2026-04 | DIN Media | |
| EN | Recommended valuesEN 1993-1-1:2005 + AC:2009 + A1:2014 | – |
Status checked on
Edition used: DIN EN 1993-1-8:2010-12 (EN 1993-1-8:2005 + AC:2009)
Status checked on
Frequently asked questions
The span, the bay width, the number of fields, the number of restrained rafters with their design compression force, the design load on the bracing, the three sections, and the steel grade. Section values come from the CALC library.
Mia solves the iteration of 5.3.3(2) exactly. The deflection follows from the stiffness of chords, diagonals, and struts by virtual work, so no estimate of delta_q is needed.
Besides the gross section, the threaded end is checked with the stress area As and Ft,Rd = 0.9 fu As / gamma_M2. For any other section with a given net area, the net section is checked with beta = 0.4 of EN 1993-1-8, Table 3.8.
Where rafters are spliced, 5.3.3(4) requires a local force of alpha_m NEd / 100 per spliced rafter. Mia checks it as a separate case together with qEd, without the stabilizing load, and the larger case governs.
Yes. On request, Mia provides a prepared RFEM 6 script that builds the truss with loads, runs the analysis and the steel design, and reproduces the utilizations.
Start with the example and adapt it to your structural system.
New calculation