Force and capacity per dowel (8.2.3, 8.6)
Distributes the tensile force evenly to every dowel and checks each one against the Johansen modes for one slotted-in plate, including timber plugs.
Privacy settings
We use Microsoft Clarity to understand how CALC is used — only if you agree. Necessary cookies keep the app working (sign-in, security, free-quota enforcement) and are always active.

SKL-000153 · Skill
EN 1995-1-1:2004+A2:2014, 8.2.3EN 1995-1-1:2004+A2:2014, 8.5.1.1EN 1995-1-1:2004+A2:2014, 8.6Enter the member, the design tensile force with its load-duration class, the slotted-in steel plate, and the dowel pattern, or read the member from your connected RFEM model. Mia checks every dowel against its Johansen capacity with nef and verifies the minimum spacings for force parallel to the grain.
Mia guides you step by stepShe guides you through the inputs and explains the results.
Check my dowelled tension connection, GL28c 100/200, one slotted-in plate 8 mm in a 10 mm slot, two dowels d = 10 mm in one column, a2 = 40 mm, a3,t = 80 mm, NEd = 3 kN short-term/instantaneous, German NA.
Distributes the tensile force evenly to every dowel and checks each one against the Johansen modes for one slotted-in plate, including timber plugs.
Reduces the dowels in a row along the grain with n_ef and leaves a single column unreduced.
Checks a1, a2, a3,t and a4,c for force parallel to the grain and marks spacings that do not apply to a single column or row.
Normative basis
The checks follow these standards. Nationally determined parameters come from the National Annex selected in the form.
Edition used: DIN EN 1995-1-1:2010-12 (EN 1995-1-1:2004 + AC:2006 + A1:2008) + DIN EN 1995-1-1/A2:2014-07
| Country | National Annex | Factors | Source |
|---|---|---|---|
| DE | DIN EN 1995-1-1/NA:2013-08Current | γM (connections) = 1.30 | DIN Media |
| EN | Recommended valuesEN 1995-1-1:2004 + AC:2006 + A1:2008 + A2:2014 | γM (connections) = 1.30 | – |
Status checked on
Frequently asked questions
The connection type, the member with strength class and section, the design tensile force with its load-duration class, the service class and the National Annex, the plate thickness and slot width, the dowel diameter and steel, and the dowel pattern with a1, a2 and a3,t.
Yes, when the Dlubal Connector is connected. Mia reads the node, the member, its section and material, and the member-end internal forces, read-only. If shear or bending act at the member end, Mia stops, because this skill covers pure tension only.
nef reduces the dowels in one row along the grain. With one column there is no spacing a1 and no reduction, so nef = 1.
With the German National Annex the load-duration class short-term/instantaneous applies, with kmod = 1.00 in service classes 1 and 2 and 0.80 in service class 3.
No. This version checks the dowels (design check 6010) and the minimum spacings. Splitting, the net section, block shear, and the steel plate are listed as not calculated, so the result never claims a fully verified connection.
Start with the example and adapt it to your structural system.
New calculation