设计 · 混凝土

柱纵向钢筋最大配筋面积

  • 类型:承载力
  • 版本1
  • 2026/11/9已审核

根据 EN 1992-1-1,柱非搭接区纵向钢筋最大配筋面积:As,max = 0.04 · Ac。

As,max=0.04⋅Ac\displaystyle A_{s,\mathrm{max}} = 0.04 \cdot A_{\mathrm{c}}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

As,max

Formula and quantities

SymbolNameUnitNote
Ac\displaystyle A_{\mathrm{c}}混凝土毛截面面积m²
As,max\displaystyle A_{s,\mathrm{max}}柱纵向钢筋最大配筋面积m²Result

实例

Ac\displaystyle A_{\mathrm{c}} = 0.09 m²

As,max\displaystyle A_{s,\mathrm{max}} = 0.0036 m² · Source: EN 1992-1-1:2004 第 9.5.2 (3) 条

Scope and standard

根据 EN 1992-1-1 第9.5.2 (3)条,柱非搭接区的钢筋混凝土柱。

Standard
EN 1992-1-1:2004,第9.5.2 (3)条
Result
As,max\displaystyle A_{s,\mathrm{max}} in m²

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
As,max\displaystyle A_{s,\mathrm{max}} = 0.0036 m²= 0.04 · (0.09 m²)