设计 · 砌体
砌体局部受压提高系数
第 1 组砌块墙体局部受压提高系数 beta:β = min((1 + 0.3 · a1 / hc) · (1.5 - 1.1 · Ab / Aef), 1.25 + a1 / (2 · hc), 1.5),>= 1.0。
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 墙端至受压面最近边缘的距离 | mm | ≥ 0 | |
| 荷载作用水平面处的墙高 | mm | > 0 | |
| 局部受压面积 | mm² | > 0 | |
| 墙体中部有效支承面积 | mm² | > 0 | |
| 局部受压提高系数 | – | Result |
Valid if
实例
= 600 mm · = 2,800 mm · = 48,000 mm² · = 240,000 mm²
= 1.35714 · Source: 手算
Scope and standard
符合 EN 1996-1-1 第 6.1.3 条承受局部荷载的第 1 组砌体块材。
- Standard
- EN 1996-1-1-2005-a1:2012,第6.1.3条,式(6.10)
- Result
- (dimensionless)
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
检索将在 设计 › 砌体 开始。