设计 · 砌体

砌体短期割线弹性模量

  • 类型:属性
  • 版本1
  • 2026/11/13已审核

由抗压强度标准值估算的砌体短期割线弹性模量:E = KE · fk。

E=KE⋅fk\displaystyle E = K_{E} \cdot f_{k}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

Formula and quantities

SymbolNameUnitNote
KE\displaystyle K_{E}弹性模量系数–KE\displaystyle K_{E} > 0
fk\displaystyle f_{k}砌体抗压强度标准值N/mm²fk\displaystyle f_{k} > 0
E\displaystyle E短期弹性模量N/mm²Result

实例

KE\displaystyle K_{E} = 1,000 · fk\displaystyle f_{k} = 5 N/mm²

E\displaystyle E = 5,000 N/mm² · Source: 手算

Scope and standard

EN 1996-1-1 第 3.7.2 条(推荐 K_E = 1000)。

Standard
EN 1996-1-1-2005-a1:2012,第3.7.2条,式(3.7)
Result
E\displaystyle E in N/mm²

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
E\displaystyle E = 5,000 N/mm²= 1,000 · (5 N/mm²)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

检索将在 设计 › 砌体 开始。

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.