设计 · 连接件

角焊缝方向法利用率 ηw

  • 类型:验算
  • 版本1
  • 2026/11/13已审核

采用方向法的角焊缝验算:ηw = √(σperp² + 3 · (τperp² + τpar²)) / (fu / (βw · γM2))。

ηw=σperp2+3⋅(τperp2+τpar2)/(fu/(βw⋅γM2))\displaystyle \eta _{w} = \sqrt{\sigma _{perp}^2 + 3 \cdot (\tau _{perp}^2 + \tau _{par}^2)} / (f_{u} / (\beta _{w} \cdot \gamma _{\mathrm{M2}}))
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

σperpτperpτparfuηw

Formula and quantities

SymbolNameUnitNote
σperp\displaystyle \sigma_{perp}垂直于焊缝有效截面的正应力N/m²
τperp\displaystyle \tau_{perp}垂直于焊缝轴线的剪应力N/m²
τpar\displaystyle \tau_{par}平行于焊缝轴线的剪应力N/m²
fu\displaystyle f_{u}被连接较弱部件的名义抗拉极限强度N/m²
βw\displaystyle \beta_{w}钢材牌号相关系数1
γM2\displaystyle \gamma_{\mathrm{M2}}焊接接头分项系数1
ηw\displaystyle \eta_{w}焊缝方向法利用率1Result

实例

σperp\displaystyle \sigma_{perp} = 120,000,000 N/m² · τperp\displaystyle \tau_{perp} = 120,000,000 N/m² · τpar\displaystyle \tau_{par} = 80,000,000 N/m² · fu\displaystyle f_{u} = 510,000,000 N/m² · βw\displaystyle \beta_{w} = 0.9 · γM2\displaystyle \gamma_{\mathrm{M2}} = 1.25

ηw\displaystyle \eta_{w} = 0.611 1

Standard and source

Result
ηw\displaystyle \eta_{w} in 1

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
ηw\displaystyle \eta_{w} = 0.611312 1= sqrt((120,000,000 N/m²)² + 3 · ((120,000,000 N/m²)² + (80,000,000 N/m²)²)) / ((510,000,000 N/m²) / ((0.9 1) · (1.25 1)))

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

检索将在 设计 › 连接件 开始。

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.