设计 · 木结构

三面受火木材有效剩余高度 (EN 1995-1-2)

  • 类型:属性
  • 版本1
  • 2026/11/21已审核

根据 EN 1995-1-2 第 4.2.2 条三面受火(底面和两侧)矩形木梁的有效剩余截面高度:hef = h - def。

hef=h−def\displaystyle h_{\mathrm{ef}} = h - d_{\mathrm{ef}}
  • EN 1995-1-2:2004
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

yzdefhef

Formula and quantities

SymbolNameUnitNote
h\displaystyle h原始木截面高度mm
def\displaystyle d_{\mathrm{ef}}有效炭化深度mm
hef\displaystyle h_{\mathrm{ef}}有效剩余高度mmResult

实例

h\displaystyle h = 400 mm · def\displaystyle d_{\mathrm{ef}} = 49 mm

hef\displaystyle h_{\mathrm{ef}} = 351 mm

Standard and source

Standard
EN 1995-1-2:2004
Result
hef\displaystyle h_{\mathrm{ef}} in mm

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
hef\displaystyle h_{\mathrm{ef}} = 351 mm= (400 mm) - (49 mm)