Design · Connections

Basic concrete blow-out resistance NRk,cb0 (EN 1992-4)

  • Type: Property
  • Version 1
  • reviewed on 11/25/2026

Basic characteristic concrete blow-out resistance for a deep headed fastener close to an edge according to EN 1992-4 Clause 7.2.1.8 Eq. (7.25): NRk,cb0 = k5 · c1 · √(Ah) · √(fck).

NRk,cb0=k5⋅c1⋅Ah⋅fck\displaystyle N_{Rk,cb0} = k_{5} \cdot c_{1} \cdot \sqrt{A_{h}} \cdot \sqrt{f_{ck}}
  • EN 1992-4:2018
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

NRkcb0c1Ahfck

Formula and quantities

SymbolNameUnitNote
k5\displaystyle k_{5}Blow-out factor (8.7 cracked, 12.2 uncracked concrete)1
c1\displaystyle c_{1}Edge distance to nearest free edgemm
Ah\displaystyle A_{h}Load-bearing area of fastener headmm²
fck\displaystyle f_{ck}Characteristic cylinder compressive strength of concreteN/m²
NRk,cb0\displaystyle N_{Rk,cb0}Basic concrete blow-out resistancekNResult

Worked example

k5\displaystyle k_{5} = 8.7 · c1\displaystyle c_{1} = 80 mm · Ah\displaystyle A_{h} = 450 mm² · fck\displaystyle f_{ck} = 30,000,000 N/m²

NRk,cb0\displaystyle N_{Rk,cb0} = 80.8679 kN

Standard and source

Standard
EN 1992-4:2018
Result
NRk,cb0\displaystyle N_{Rk,cb0} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
NRk,cb0\displaystyle N_{Rk,cb0} = 80.8679 kN= (8.7 1) · ((80 mm) / 1 [mm]) · sqrt((450 mm²) / 1 [mm²]) · sqrt((30,000,000 N/m²) / 1 [MPa]) · 1 [N]

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Connections.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.