Cross-sections · Closed thin-walled sections

Thin-walled torsional constant of a CHS

  • Type: Property
  • Version 1

Thin-walled formula for torsional constant: It = π · (d - t)³ · t / 4.

It=π⋅(d−t)3⋅t4\displaystyle I_{t} = \frac{\pi \cdot (d - t)^3 \cdot t}{4}
  • General formula, independent of standards
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

yzdt

Formula and quantities

SymbolNameUnitNote
d\displaystyle dDiametermmd\displaystyle d > 0
t\displaystyle tWall thicknessmmt\displaystyle t > 0
It\displaystyle I_{t}Torsional constantcm⁴Result

Valid if2⋅t<d\displaystyle 2 \cdot t < d

Worked example

d\displaystyle d = 100 mm · t\displaystyle t = 5 mm

It\displaystyle I_{t} = 336.688 cm⁴ · Source: hand calculation: pi · 95³ · 5 / 4 = 3366882 mm⁴

Scope and standard

Thin-walled circular hollow section, t << d.

Result
It\displaystyle I_{t} in cm⁴

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
It\displaystyle I_{t} = 336.69 cm⁴= pi · ((100 mm) - (5 mm))³ · (5 mm) / 4

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Cross-sections › Closed thin-walled sections.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.