Design · Composite

Composite column effective concrete modulus Ec,eff (EN 1994-1-1)

  • Type: Property
  • Version 1
  • reviewed on 11/25/2026

Effective elastic modulus of concrete accounting for long-term creep and shrinkage in composite columns according to EN 1994-1-1 Clause 6.7.3.3 Eq. (6.41): Ec,eff = Ecm / (1 + (NG,Ed / NEd) · φt).

Ec,eff=Ecm/(1+(NG,Ed/NEd)⋅ϕt)\displaystyle E_{\mathrm{c},\mathrm{eff}} = E_{cm} / (1 + (N_{G,\mathrm{Ed}} / N_{\mathrm{Ed}}) \cdot \phi _{t})
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

NEdφt

Formula and quantities

SymbolNameUnitNote
Ecm\displaystyle E_{cm}Secant modulus of elasticity of concreteN/m²
NG,Ed\displaystyle N_{G,\mathrm{Ed}}Permanent part of design axial loadkN
NEd\displaystyle N_{\mathrm{Ed}}Total design axial loadkN
ϕt\displaystyle \phi_{t}Final creep coefficient1
Ec,eff\displaystyle E_{\mathrm{c},\mathrm{eff}}Effective long-term concrete modulusN/m²Result

Worked examples

C30/37 column 60% permanent

Ecm\displaystyle E_{cm} = 33,000,000,000 N/m² · NG,Ed\displaystyle N_{G,\mathrm{Ed}} = 1,200 kN · NEd\displaystyle N_{\mathrm{Ed}} = 2,000 kN · ϕt\displaystyle \phi_{t} = 2

Ec,eff\displaystyle E_{\mathrm{c},\mathrm{eff}} = 15,000,000,000 N/m²

C40/50 column 50% permanent

Ecm\displaystyle E_{cm} = 35,000,000,000 N/m² · NG,Ed\displaystyle N_{G,\mathrm{Ed}} = 1,500 kN · NEd\displaystyle N_{\mathrm{Ed}} = 3,000 kN · ϕt\displaystyle \phi_{t} = 1.5

Ec,eff\displaystyle E_{\mathrm{c},\mathrm{eff}} = 20,000,000,000 N/m²

Standard and source

Standard
EN 1994-1-1:2004, clause 6.7.3.3, Eq. (6.41)
Result
Ec,eff\displaystyle E_{\mathrm{c},\mathrm{eff}} in MPa

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Ec,eff\displaystyle E_{\mathrm{c},\mathrm{eff}} = 15,000,000,000 N/m²= (33,000,000,000 N/m²) / (1 + ((1,200 kN) / (2,000 kN)) · (2 1))

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Composite.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.