Design · Concrete

Minimum first order eccentricity e0

  • Type: Property
  • Version 1
  • reviewed on 11/12/2026

Minimum design eccentricity for cross-sections in compression to EN 1992-1-1 Clause 6.1 (4): e0 = max(h/30, 20 mm).

e0=max⁡(h30,20 mm)\displaystyle e_{0} = \max\left(\frac{h}{30}, 20\text{ mm}\right)
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

h

Formula and quantities

SymbolNameUnitNote
h\displaystyle hOverall section depth in considered directionmm
e0\displaystyle e_{0}Minimum first order eccentricitymmResult

Worked examples

h=450 mm -> e0=20 mm

h\displaystyle h = 450 mm

e0\displaystyle e_{0} = 20 mm · Source: EN 1992-1-1:2004 clause 6.1 (4)

h=900 mm -> e0=30 mm

h\displaystyle h = 900 mm

e0\displaystyle e_{0} = 30 mm · Source: EN 1992-1-1:2004 clause 6.1 (4)

Scope and standard

Reinforced concrete columns to EN 1992-1-1.

Standard
EN 1992-1-1:2004, clause 6.1 (4)
Result
e0\displaystyle e_{0} in mm

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
e0\displaystyle e_{0} = 20 mm= max((450 mm) / 30; 20 [mm])

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Concrete.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.