Design · Concrete
Minimum first order eccentricity e0
Minimum design eccentricity for cross-sections in compression to EN 1992-1-1 Clause 6.1 (4): e0 = max(h/30, 20 mm).
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Overall section depth in considered direction | mm | ||
| Minimum first order eccentricity | mm | Result |
Worked examples
h=450 mm -> e0=20 mm
= 450 mm
= 20 mm · Source: EN 1992-1-1:2004 clause 6.1 (4)
h=900 mm -> e0=30 mm
= 900 mm
= 30 mm · Source: EN 1992-1-1:2004 clause 6.1 (4)
Scope and standard
Reinforced concrete columns to EN 1992-1-1.
- Standard
- EN 1992-1-1:2004, clause 6.1 (4)
- Result
- in mm
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
- Explain the formulastep by step
- Calculate for my dimensionsenter values, check the result
- Compare with a catalog sectionformula value and table value
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
The search starts in Design › Concrete.
Miaknows the formula catalog and asks for what is missing.