Design · Concrete

Punching shear resistance without reinforcement vRd,c

  • Type: Resistance
  • Version 1
  • reviewed on 11/10/2026

Design punching shear resistance along the basic control perimeter without shear reinforcement to EN 1992-1-1 Eq. (6.47).

vRd,c=CRd,c⋅k⋅(100⋅ρl⋅fck1 MPa)1/3⋅1 MPa+k1⋅σcp\displaystyle v_{\mathrm{Rd},\mathrm{c}} = C_{\mathrm{Rd},\mathrm{c}} \cdot k \cdot \left(100 \cdot \rho_{l} \cdot \frac{f_{ck}}{1\,\text{MPa}}\right)^{1/3} \cdot 1\,\text{MPa} + k_{1} \cdot \sigma_{cp}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

vRd,c

Formula and quantities

SymbolNameUnitNote
CRd,c\displaystyle C_{\mathrm{Rd},\mathrm{c}}Calibration coefficient for punching–
k\displaystyle kSize effect factor for punching–
ρl\displaystyle \rho_{l}Mean longitudinal reinforcement ratio–
fck\displaystyle f_{ck}Characteristic concrete cylinder strengthN/mm²
k1\displaystyle k_{1}Coefficient for normal stress in slab–
σcp\displaystyle \sigma_{cp}Mean normal stress in slabN/mm²
vRd,c\displaystyle v_{\mathrm{Rd},\mathrm{c}}Punching shear resistance without reinforcementN/mm²Result

Worked example

CRd,c\displaystyle C_{\mathrm{Rd},\mathrm{c}} = 0.12 · k\displaystyle k = 1.8 · ρl\displaystyle \rho_{l} = 0.012 · fck\displaystyle f_{ck} = 30 N/mm² · k1\displaystyle k_{1} = 0.1 · σcp\displaystyle \sigma_{cp} = 0 N/mm²

vRd,c\displaystyle v_{\mathrm{Rd},\mathrm{c}} = 0.713 N/mm² · Source: EN 1992-1-1:2004 Eq. (6.47)

Scope and standard

Slabs and column bases subjected to punching shear to EN 1992-1-1.

Standard
EN 1992-1-1:2004, clause 6.4.4 (1), Eq. (6.47)
Result
vRd,c\displaystyle v_{\mathrm{Rd},\mathrm{c}} in N/mm²

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
vRd,c\displaystyle v_{\mathrm{Rd},\mathrm{c}} = 0.713216 N/mm²= 0.12 · 1.8 · ((100 · 0.012 · ((30 N/mm²) / 1 [MPa])) ^ (1 / 3)) · 1 [MPa] + 0.1 · (0 N/mm²)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Concrete.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.