Design · Concrete

Applied punching shear stress vEd

  • Type: Action effect
  • Version 1
  • reviewed on 11/9/2026

Maximum applied punching shear stress along the control perimeter u1: vEd = β · VEd / (u1 · d).

vEd=β⋅VEdu1⋅d\displaystyle v_{\mathrm{Ed}} = \frac{\beta \cdot V_{\mathrm{Ed}}}{u_{1} \cdot d}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

du1VEdvEdβ

Formula and quantities

SymbolNameUnitNote
β\displaystyle \betaLoad eccentricity factor–
VEd\displaystyle V_{\mathrm{Ed}}Design punching shear forcekN
u1\displaystyle u_{1}Length of control perimeterm
d\displaystyle dMean effective depth of slabm
vEd\displaystyle v_{\mathrm{Ed}}Applied punching shear stressN/mm²Result

Worked example

β\displaystyle \beta = 1.15 · VEd\displaystyle V_{\mathrm{Ed}} = 500 kN · u1\displaystyle u_{1} = 4 m · d\displaystyle d = 0.2 m

vEd\displaystyle v_{\mathrm{Ed}} = 0.71875 N/mm² · Source: EN 1992-1-1:2004 Eq. (6.38)

Scope and standard

Flat slabs and column bases under punching shear according to EN 1992-1-1, clause 6.4.3.

Standard
EN 1992-1-1:2004, clause 6.4.3 (3), Eq. (6.38)
Result
vEd\displaystyle v_{\mathrm{Ed}} in N/mm²

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
vEd\displaystyle v_{\mathrm{Ed}} = 0.71875 N/mm²= 1.15 · (500 kN) / ((4 m) · (0.2 m))

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Concrete.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.