Design · Concrete

Torsional stirrups per unit length Asw/s

  • Type: Property
  • Version 1
  • reviewed on 11/10/2026

Required torsional link reinforcement per unit length according to EN 1992-1-1 Eq. (6.26).

Aswts=TEd2⋅Ak⋅fywd⋅cot⁡θ\displaystyle \frac{A_{swt}}{s} = \frac{T_{\mathrm{Ed}}}{2 \cdot A_{k} \cdot f_{ywd} \cdot \cot \theta}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

aswt

Formula and quantities

SymbolNameUnitNote
TEd\displaystyle T_{\mathrm{Ed}}Design torsional momentNm
Ak\displaystyle A_{k}Area enclosed by the centerlinesmm²
fywd\displaystyle f_{ywd}Design yield strength of linksN/mm²
cot⁡θ\displaystyle \cot \thetaCotangent of strut angle–
aswt\displaystyle a_{swt}Required torsional link area per lengthmmResult

Worked example

TEd\displaystyle T_{\mathrm{Ed}} = 30,000 Nm · Ak\displaystyle A_{k} = 120,000 mm² · fywd\displaystyle f_{ywd} = 435 N/mm² · cot⁡θ\displaystyle \cot \theta = 1.5

aswt\displaystyle a_{swt} = 0.1916 mm · Source: EN 1992-1-1:2004 Eq. (6.26)

Scope and standard

Concrete beams with torsional shear reinforcement to EN 1992-1-1.

Standard
EN 1992-1-1:2004, clause 6.3.2 (3), Eq. (6.26)
Result
aswt\displaystyle a_{swt} in mm²/mm

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
aswt\displaystyle a_{swt} = 0.191571 mm= (30,000 Nm) / (2 · (120,000 mm²) · (435 N/mm²) · 1.5)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Concrete.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.