Structural analysis · Columns and stability
Euler buckling load for Euler case 2 (pinned-pinned column)
Euler critical elastic buckling load of a column pinned at both ends (Euler case 2, effective length s = l): Ncr = (π² · E · I) / l².
- General formula, independent of standards
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Modulus of elasticity | N/m² | ||
| Second moment of area | cm⁴ | ||
| Column length | m | ||
| Euler critical buckling load | kN | Result |
Worked example
= 210,000,000,000 N/m² · = 8,356 cm⁴ · = 4 m
= 10,820 kN · Source: hand calculation: pi² · 21000 · 8356 / 400² = 10819.96 kN
Scope and standard
Euler case 2 column (pinned-pinned), elastic buckling.
- Result
- in kN
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
- Explain the formulastep by step
- Calculate for my dimensionsenter values, check the result
- Compare with a catalog sectionformula value and table value
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
The search starts in Structural analysis › Columns and stability.
Miaknows the formula catalog and asks for what is missing.