Actions and loads · Thermal actions

External fire temperature-time curve (EN 1991-1-2)

  • Type: Property
  • Version 1
  • reviewed on 11/21/2026

Gas temperature for external structural members exposed to an external fire according to EN 1991-1-2 Clause 3.2.2 Eq. (3.5): Θg = 660 · (1 - 0.687 · exp(-0.32 · t) - 0.313 · exp(-3.8 · t)) + 20.

Θg=660⋅(1−0.687e−0.32t−0.313e−3.8t)+20\displaystyle \Theta_{g} = 660 \cdot \left(1 - 0.687 e^{-0.32 t} - 0.313 e^{-3.8 t}\right) + 20
  • EN 1991-1-2:2002
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

Θg

Try it

Θg\displaystyle \Theta_{g} = 679.969 1= 660 · (1 - 0.687 · exp(-0.32 · ((30 min) / [min])) - 0.313 · exp(-3.8 · ((30 min) / [min]))) + 20

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Actions and loads › Thermal actions.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.