Actions and loads · Combinations of actions

SLS frequent combination

  • Type: Combination
  • Version 1

Serviceability limit state frequent combination for reversible limit states.

Ed=Gk+ψ1⋅Qk,1+ψ2⋅Qk,2\displaystyle E_{\mathrm{d}} = G_{k} + \psi_{1} \cdot Q_{k,1} + \psi_{2} \cdot Q_{k,2}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

GkQk,1Qk,2Ed

Formula and quantities

SymbolNameUnitNote
Gk\displaystyle G_{k}Characteristic permanent actionkN
ψ1\displaystyle \psi_{1}Frequent value factor for leading action–
Qk,1\displaystyle Q_{k,1}Characteristic leading variable actionkN
ψ2\displaystyle \psi_{2}Quasi-permanent factor for accompanying action–
Qk,2\displaystyle Q_{k,2}Characteristic accompanying variable actionkN
Ed\displaystyle E_{\mathrm{d}}Frequent SLS action effectkNResult

Worked example

Gk\displaystyle G_{k} = 100 kN · ψ1\displaystyle \psi_{1} = 0.5 · Qk,1\displaystyle Q_{k,1} = 50 kN · ψ2\displaystyle \psi_{2} = 0.3 · Qk,2\displaystyle Q_{k,2} = 30 kN

Ed\displaystyle E_{\mathrm{d}} = 134 kN · Source: hand calculation

Scope and standard

Eurocode 0 (EN 1990:2002) Eq. (6.15b).

Standard
EN 1990:2002
Result
Ed\displaystyle E_{\mathrm{d}} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Ed\displaystyle E_{\mathrm{d}} = 134 kN= (100 kN) + 0.5 · (50 kN) + 0.3 · (30 kN)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Actions and loads › Combinations of actions.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.