Geotechnics · Earth pressure

At-rest earth pressure ordinate e0 (EN 1997-1)

  • Type: Action
  • Version 1
  • reviewed on 11/24/2026

Horizontal earth pressure ordinate at rest at depth z in homogeneous cohesionless soil according to EN 1997-1 Clause 9.5.2: e0 = K0 · γ · z.

e0=K0⋅γ⋅z\displaystyle e_{0} = K_{0} \cdot \gamma \cdot z
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

e0z

Formula and quantities

SymbolNameUnitNote
K0\displaystyle K_{0}At-rest earth pressure coefficient1
γ\displaystyle \gammaUnit weight of soilkN/m³
z\displaystyle zDepth below ground surfacem
e0\displaystyle e_{0}At-rest horizontal earth pressure ordinateN/m²Result

Worked example

K0\displaystyle K_{0} = 0.5 1 · γ\displaystyle \gamma = 18 kN/m³ · z\displaystyle z = 4 m

e0\displaystyle e_{0} = 36,000 N/m²

Standard and source

Result
e0\displaystyle e_{0} in kPa

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
e0\displaystyle e_{0} = 36,000 N/m²= (0.5 1) · (18 kN/m³) · (4 m)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Geotechnics › Earth pressure.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.