Bearing capacity factor for surcharge: Nq = exp(π · tan(phi')) · tan²(45 deg + phi'/2).

Nq=eπ⋅tan⁡(φ′)⋅tan⁡2(45∘+φ′2)\displaystyle N_{q} = \mathrm{e}^{\pi \cdot \tan(\varphi')} \cdot \tan^2\left(45^\circ + \frac{\varphi'}{2}\right)
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

φ'Nq

Formula and quantities

SymbolNameUnitNote
φ′\displaystyle \varphi'Effective friction angle of soil°
Nq\displaystyle N_{q}Bearing capacity factor N_q–Result

Worked example

φ′\displaystyle \varphi' = 30 °

Nq\displaystyle N_{q} = 18.4011 · Source: EN 1997-1:2004 Annex D

Scope and standard

Bearing resistance of shallow foundations according to EN 1997-1, Annex D.

Standard
EN 1997-1:2004, clause D.4, Eq. (D.2)
Result
Nq\displaystyle N_{q} (dimensionless)

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Nq\displaystyle N_{q} = 18.4011= exp(pi · tan((30 °))) · tan(45 [deg] + (30 °) / 2)²