Geotechnics · Bearing resistance

Effective foundation length L'

  • Type: Property
  • Version 1
  • reviewed on 11/10/2026

Effective foundation length taking eccentricity into account: L' = L - 2 · eL.

L′=L−2⋅eL\displaystyle L' = L - 2 \cdot e_{L}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

eLLL'

Formula and quantities

SymbolNameUnitNote
L\displaystyle LFoundation lengthm
eL\displaystyle e_{L}Load eccentricity in length directionm
L′\displaystyle L'Effective foundation lengthmResult

Worked example

L\displaystyle L = 3 m · eL\displaystyle e_{L} = 0.15 m

L′\displaystyle L' = 2.7 m · Source: EN 1997-1:2004 Eq. (6.1)

Scope and standard

Shallow foundations under eccentric loading according to EN 1997-1, clause 6.5.2.2.

Standard
EN 1997-1:2004, clause 6.5.2.2 (1), Eq. (6.1)
Result
L′\displaystyle L' in m

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
L′\displaystyle L' = 2.7 m= (3 m) - 2 · (0.15 m)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Geotechnics › Bearing resistance.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.