Geotechnics · Settlement
Hydraulic heave verification ratio (HYD)
Verification against failure by hydraulic heave (HYD): ηHYD = ud / σd <= 1.0.
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Design pore water pressure at bottom of low permeability layer | N/m² | ||
| Design total overburden vertical stress | N/m² | ||
| Hydraulic heave verification ratio | – | Result |
Worked example
= 40,000 N/m² · = 50,000 N/m²
= 0.8 · Source: EN 1997-1:2004 clause 2.4.7.5
Scope and standard
Hydraulic failure (HYD) limit state according to EN 1997-1 Clause 2.4.7.5 and 10.3.
- Standard
- EN 1997-1:2004, clause 2.4.7.5, Eq. (2.10)
- Result
- (dimensionless)
Reference to clause and equation, no standard text. The description is written in our own words.