Geotechnics · Bearing resistance

Load inclination factor ic (undrained)

  • Type: Coefficient
  • Version 1
  • reviewed on 11/12/2026

Load inclination factor ic for undrained bearing resistance: ic = 0.5 · (1 + √(1 - H / (A' · cu))).

ic=12⋅(1+1−HA′⋅cu)\displaystyle i_{\mathrm{c}} = \frac{1}{2} \cdot \left(1 + \sqrt{1 - \frac{H}{A' \cdot c_{u}}}\right)
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

Hcuic

Formula and quantities

SymbolNameUnitNote
H\displaystyle HHorizontal load on foundationkN
A′\displaystyle A'Effective foundation aream²
cu\displaystyle c_{u}Undrained shear strength of soilN/m²
ic\displaystyle i_{\mathrm{c}}Undrained inclination factor i_c–Result

Worked example

H\displaystyle H = 200 kN · A′\displaystyle A' = 10 m² · cu\displaystyle c_{u} = 50,000 N/m²

ic\displaystyle i_{\mathrm{c}} = 0.8873 · Source: EN 1997-1:2004 Annex D

Scope and standard

Undrained bearing capacity of shallow foundations according to EN 1997-1 Annex D.

Standard
EN 1997-1:2004, clause D.3, Eq. (D.1)
Result
ic\displaystyle i_{\mathrm{c}} (dimensionless)

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
ic\displaystyle i_{\mathrm{c}} = 0.887298= 0.5 · (1 + sqrt(1 - (200 kN) / ((10 m²) · (50,000 N/m²))))

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Geotechnics › Bearing resistance.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.