Geotechnics · Bearing resistance
Load inclination factor ic (undrained)
Load inclination factor ic for undrained bearing resistance: ic = 0.5 · (1 + √(1 - H / (A' · cu))).
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Horizontal load on foundation | kN | ||
| Effective foundation area | m² | ||
| Undrained shear strength of soil | N/m² | ||
| Undrained inclination factor i_c | – | Result |
Worked example
= 200 kN · = 10 m² · = 50,000 N/m²
= 0.8873 · Source: EN 1997-1:2004 Annex D
Scope and standard
Undrained bearing capacity of shallow foundations according to EN 1997-1 Annex D.
- Standard
- EN 1997-1:2004, clause D.3, Eq. (D.1)
- Result
- (dimensionless)
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
- Explain the formulastep by step
- Which value applies to my case?clarify the boundary conditions
- Limits and special caseswhen the formula does not apply
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
The search starts in Geotechnics › Bearing resistance.
Miaknows the formula catalog and asks for what is missing.