Characteristic base resistance of a compressive pile: Rbk = qbk · Ab.

Rb,k=qb,k⋅Ab\displaystyle R_{\mathrm{b},k} = q_{\mathrm{b},k} \cdot A_{\mathrm{b}}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

qb,kRb,kAb

Formula and quantities

SymbolNameUnitNote
qb,k\displaystyle q_{\mathrm{b},k}Characteristic unit base resistanceN/m²
Ab\displaystyle A_{\mathrm{b}}Cross-sectional area of pile basem²
Rb,k\displaystyle R_{\mathrm{b},k}Characteristic base resistancekNResult

Worked example

qb,k\displaystyle q_{\mathrm{b},k} = 2,500,000 N/m² · Ab\displaystyle A_{\mathrm{b}} = 0.2 m²

Rb,k\displaystyle R_{\mathrm{b},k} = 500 kN · Source: EN 1997-1:2004 clause 7.6.2.3

Scope and standard

Pile foundations design from ground test parameters according to EN 1997-1 Clause 7.6.2.3.

Standard
EN 1997-1:2004, clause 7.6.2.3, Eq. (7.10)
Result
Rb,k\displaystyle R_{\mathrm{b},k} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Rb,k\displaystyle R_{\mathrm{b},k} = 500 kN= (2,500,000 N/m²) · (0.2 m²)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Geotechnics › Bearing resistance.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.