Cross-sections · Open thin-walled sections

Flange area contribution ratio of an I-section

  • Type: Property
  • Version 1

Ratio of total flange area to total section area: Af / A = (2 · b · tf) / (2 · b · tf + (h - 2 · tf) · tw).

AfA=2⋅b⋅tf2⋅b⋅tf+(h−2⋅tf)⋅tw\displaystyle \frac{A_{f}}{A} = \frac{2 \cdot b \cdot t_{f}}{2 \cdot b \cdot t_{f} + (h - 2 \cdot t_{f}) \cdot t_{w}}
  • General formula, independent of standards
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

yzbhtftw

Formula and quantities

SymbolNameUnitNote
h\displaystyle hDepthmmh\displaystyle h > 0
b\displaystyle bWidthmmb\displaystyle b > 0
tw\displaystyle t_{w}Web thicknessmmtw\displaystyle t_{w} > 0
tf\displaystyle t_{f}Flange thicknessmmtf\displaystyle t_{f} > 0
Af/A\displaystyle A_{f}/AFlange area ratio–Result

Valid if2⋅tf<h\displaystyle 2 \cdot t_{f} < htw<b\displaystyle t_{w} < b

Worked example

h\displaystyle h = 300 mm · b\displaystyle b = 150 mm · tw\displaystyle t_{w} = 8 mm · tf\displaystyle t_{f} = 12 mm

Af/A\displaystyle A_{f}/A = 0.6198 · Source: hand calculation: 3600 / (3600 + 2208) = 0.61983

Scope and standard

Doubly-symmetric I-section.

Result
Af/A\displaystyle A_{f}/A (dimensionless)

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Af/A\displaystyle A_{f}/A = 0.619835= (2 · (150 mm) · (12 mm)) / (2 · (150 mm) · (12 mm) + ((300 mm) - 2 · (12 mm)) · (8 mm))

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Cross-sections › Open thin-walled sections.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.