Actions and loads · Imposed loads

Imposed load reduction factor for loaded area

  • Type: Coefficient
  • Version 2
  • reviewed on 11/10/2026

Reduction factor αA for uniformly distributed imposed loads on large tributary areas according to EN 1991-1-1 Clause 6.3.1.2 Eq. (6.1).

αA=min((5/7)⋅ψ0+A0/A,1.0)\displaystyle \alpha _{\mathrm{A}} = min((5 / 7) \cdot \psi _{0} + A_{0} / A, 1.0)
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

AαA

Formula and quantities

SymbolNameUnitNote
ψ0\displaystyle ψ_{0}Combination factor–
A0\displaystyle A_{0}Reference tributary aream²
A\displaystyle ALoaded tributary aream²
αA\displaystyle α_{\mathrm{A}}Area reduction factor–Result

Worked examples

ψ0\displaystyle ψ_{0} = 0.7 · A0\displaystyle A_{0} = 10 m² · A\displaystyle A = 50 m²

αA\displaystyle α_{\mathrm{A}} = 0.7

ψ0\displaystyle ψ_{0} = 0.7 · A0\displaystyle A_{0} = 10 m² · A\displaystyle A = 15 m²

αA\displaystyle α_{\mathrm{A}} = 1

Standard and source

Standard
EN 1991-1-1:2002, clause 6.3.1.2
Result
αA\displaystyle α_{\mathrm{A}} (dimensionless)

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
αA\displaystyle α_{\mathrm{A}} = 0.7= min((5 / 7) · 0.7 + (10 m²) / (50 m²); 1)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Actions and loads › Imposed loads.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.