Actions and loads · Imposed loads

Total floor imposed load including movable partitions

  • Type: Action
  • Version 1
  • reviewed on 11/10/2026

Total equivalent imposed floor load qtot = qk + qpart including uniformly distributed movable partition allowance according to EN 1991-1-1 Clause 6.3.1.2(8).

qtot=qk+qpart\displaystyle q_{tot} = q_{k} + q_{part}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

qtot

Formula and quantities

SymbolNameUnitNote
qk\displaystyle q_{k}Base imposed loadkN/m²
qpart\displaystyle q_{part}Movable partition allowancekN/m²
qtot\displaystyle q_{tot}Total floor imposed loadkN/m²Result

Worked example

qk\displaystyle q_{k} = 2.5 kN/m² · qpart\displaystyle q_{part} = 0.8 kN/m²

qtot\displaystyle q_{tot} = 3.3 kN/m²

Standard and source

Standard
EN 1991-1-1:2002, clause 6.3.1.2
Result
qtot\displaystyle q_{tot} in kN/m²

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
qtot\displaystyle q_{tot} = 3.3 kN/m²= (2.5 kN/m²) + (0.8 kN/m²)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Actions and loads › Imposed loads.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.