Actions and loads · Permanent actions

Self-weight of a member from unit weight

  • Type: Action
  • Version 1

Nominal linear self-weight per unit length calculated from cross-sectional area and unit weight: gk = γ · A.

gk=γ⋅A\displaystyle g_{k} = \gamma \cdot A
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

gkAγ

Formula and quantities

SymbolNameUnitNote
γ\displaystyle \gammaUnit weightkN/m³
A\displaystyle ACross-sectional areacm²
gk\displaystyle g_{k}Nominal self-weightkN/mResult

Worked example

γ\displaystyle \gamma = 25 kN/m³ · A\displaystyle A = 1,200 cm²

gk\displaystyle g_{k} = 3 kN/m · Source: hand calculation: 25 kN/m³ · 0.12 m² = 3.0 kN/m

Scope and standard

Prismatic structural members with uniform density.

Result
gk\displaystyle g_{k} in kN/m

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
gk\displaystyle g_{k} = 3 kN/m= (25 kN/m³) · (1,200 cm²)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Actions and loads › Permanent actions.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.